S.P.E. CBHD1-XR-M Manual Del Usuario página 11

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
ERROR MESSAGES ON THE DISPLAY
In the event of anomalies, the following error codes may be displayed.
ERROR CODE
Srt:IB > IBmax
E01:Open Circuit
E02: Temperature
E03:timer
Ref.
Shown is an example of how an "E02: Temperature error
will be displayed.
D00240-02
PROBLEM
The output current
has exceeded the
nominal current value
by more than 10%
The current suddenly
went to zero
unexpectedly
The internal thermal
sensor has detected
high temperature.
The safety timer of
one of the phases
has been activated
Messages reported
Phase timeout or too
much current
No Battery
Inversion of polarity
Battery in Short
Circuit
Incorrect Battery
Voltage
Over temperature
error
Corrupted charging
profile
SOLUTIONS
Make sure there are no short circuits on the battery or the battery
cables or there is an active load on the battery that draws more
current than the charger can provide
Check the connection of the clamps to the battery and check the
voltage of the battery elements to make sure that there are no
elements in an open circuit condition. The charger starts again after
5 seconds.
Use the charger in a well ventilated area
Make sure that a suitable charging current has been set for the
battery capacity and that the selected voltage corresponds to the
voltage of the battery. Also make sure that there are no elements in
short circuit and that the battery is not sulphated.
DL3 LED (red)
BLK
OFF
OFF
OFF
OFF
BLK
BLK
DL2 LED (yellow)
OFF
BLK
BLK
BLK
BLK
OFF
OFF
User Manual
DL1 LED (green)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
11