Cooke & Lewis CLCER60A Manual De Instrucciones página 96

Ocultar thumbs Ver también para CLCER60A:
Installation
EN General
All installation must be carried out by a competent person or qualified electrician. Before connecting the
mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
The appliance must be connected directly to the mains using an omnipolar circuit-breaker with a minimum
opening of 3 mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it complies with
the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage. If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a safety
hazard.
WARNING: This is a Class I appliance and MUST be earthed.
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
N
N
N
(Blue)
L
(Brown)
(Green/Yellow)
This appliance must be connected directly to the mains consumer unit and protected by a 32 Amp
Residual Current Device (RCD).
To avoid the risks that are always present when you use an electrical appliance it is important that this
appliance is installed correctly and that you read the safety instructions carefully to avoid misuse and
hazards. Please keep this instruction booklet for future reference and pass it on to any future owners.
After unpacking the appliance please check that it is not damaged. If in doubt, do not use the appliance but
contact Customer Services - see end of Care & Maintenance section for details.
211827_s1_s7-3663602429517-C&L-A5-IM-Easy-V02.indd 16
L
L
N
L
220-240V~
21-09-2021 13:05:19
16