The spotlight must shine in the opposite direction to the house or terrace to avoid the lighting being too harsh.
The spotlight must be positioned 60cm maximum under the rim of the pool, measured from the axis of the bulb. The spotlight
recess is supplied with two 3/4" outputs. The rear output is generally used for brick-built pools and the vertical output for
panel-built pools.
Brick and liner structure
• Install the construction protection on the front of the recess.
• Seal the spotlight recess in the brickwork. Finish the plaster flush with the front surface, making sure the recess is
orientated upwards. Block the unused outlet using the plug.
• Install the seal on the front of the spotlight recess.
• Install the seal on the spotlight recess flange.
• Attach the sealing flange after the liner has been installed.
• Cut the liner
Panel and liner structure
• Use the template to drill the panel
• Install the spotlight recess from inside the pool. Screw it onto the panel after installing the foam, placing the spotlight unit
fastening grooves in a horizontal position.
• Seal the liner, the sheath and the cable and install the spotlight unit in the same way as the liner spotlight.
Brick structure without liner
• Seal the spotlight recess into the brickwork, with the front part set back to allow the finishing plaster or tiling to be installed.
• Seal the liner, the sheath and the cable and install the spotlight unit in the same way as the liner spotlight.
Installing the spotlight
• Pass the spotlight unit cable through the cable gland. Ensure the cable gland fitting is correctly positioned.
• Push the spotlight unit cable through the sheath to the terminal box.
• Seal the cable with the cable gland. Ensure the cable gland fitting is in the correct position. (the 30° end is positioned in
the bottom of the cable gland body).
• Hold the spotlight in front of the recess, winding the extra cable into it.
• Ensure the spotlight is in the right position in the recess by aligning the marker on the glass vertically, with the arrow
pointing upwards.
• Fit the spotlight into the recess, placing the prongs into the grooves.
Transformer power
The transformer to be used must have a secondary voltage of 12V (12.5V depending on the model). The power must
be suitable for the power of the spotlight(s) to be connected.
In all cases, the total power of the spotlights must be less than or equal to the power of the transformer.
Each spotlight requires individual protection. Protection must be provided for the transformer secondary winding using 3A
or 5A fuses or circuit breakers (see wiring diagram below).
Example with 2
spotlights
Page 3 of 4
INSTALLATION
230V
12V
3A protection
Spotlight 1
Spotlight 2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
ColorLogic II / CrystaLogic
3A protection
L
N
230V
Example with 1
spotlight
12V
3A protection
Spotlight 1
Rev. B