JBM 54290 Manual De Instrucciones página 20

Idiomas disponibles

Idiomas disponibles

If the test is not successful, the screen will display the opera-
tions which need to be performed:
Not enough new oil in the bottle. Please put more oil in the
tank.
Too much old oil in the bottle. Press ENTER to continue.
Open the oil drain valve and press ENTER.
The screen will show how the machine is emptying the old
oil bottle.
The system starts to drain the used fluid.
You can press RETURN key to stop the operation and return
to the previous menu.
The interface prompts "Emptying OK!" after the testing is
passed.
Press ENTER key to proceed with transmission fluid exchange.
The screen will display the progress bar and the waveforms
for the change of new/used fluid.
After the exchange is finished, the screen will display:
- Amount of the new fluid changed
- Amount of the used fluid changed
- Error between them
Press RETURN key to return to the previous menu.
Then, please do the following:
1. Check the fluid level inside transmission. If the level is
not enough, supplying fluid is required (refer to the section
"Adjust fluid level")
2. Disconnect the unit from the vehicle and connect again
the hoses of the vehicle's transmission.
3. Start the engine and check if there is oil leakage in the
vehicle's pipelines.
Note:
It is recommended to switch each gear when exchanging.
The time of each shift should be about half minute.
To ensure the exchange quality, the quantity of new fluid
inside the unit should be 2L~3L more than that of the fluid
required by automatic transmission.
Do not add new fluid to the tank during the exchange
process. If you need to add more fluid, wait until the process
is finished.