Hendi 230299 Manual Del Usuario página 6

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 214
Connection to the water supply
ATTENTION: The connection with the water sup-
ply should be made according to the current safety
standards.
The dishwasher may be connected to water sup-
ply with maximum inlet temperature 60°C/130°F.
In case you need connection with water supply of
high temperature please contact our Factory or
our distributor or our local dealer.
• The water supply hose should have a flap valve
(non-return valve) according to DIN 1988.
• The water supply hose/pipe should be rinsed be-
Drainage connection
• The outflow is accomplished through gravity
force (natural flow). The outlet hose should be
connected either directly to the main drainage -
where a pipette for odours is anticipated, or wa-
ter runs directly to a drainage well in the ground,
which has a pipette for odours.
Electrical Network connection
ATTENTION: All electrical work must be carried
out by a suitably qualified and competent person.
EN
• The dishwasher operates under specific voltage
depending on the type of the dishwasher.
• You should supply the power, depending on the
appliance's power reception (the electrical con-
nection should be made by authorized electri-
cians). Specifications should be met according
Protective duct connection and voltage compensation
• The electrical safety of this appliance is ensured
only if the protective duct has been connected
and checked properly. The corresponding spec-
ifications should be met at this point (see para-
graph 1.5).
• In addition, the appliance should include a volt-
age compensation system.
6
fore the appliance's connection.
• The water supply hose/pipe should have a min-
imum internal diameter of 16 mm and the con-
nection with the hose should be 3/4 inch.
• All hose collars should be adjusted in a fixed po-
sition before the appliance is put into operation.
• The dishwasher can be only connected to a
well-functioning softener.
ATTENTION: The water pressure must be between
2 and 5 bar.
ATTENTION: The outlet hose should not be placed
higher than a level (as given for each appliance's
type) from the lower side of the dishwasher's dis-
penser.
to the corresponding parts of DIN, VDE, D100,
the EVU connection terms, the relevant ZH 1/37,
chapter 7.2 - as well as the current specifications
for accident prevention.
• Respectively, the appliance must be connected
to a direct power supply electrical installation
through an HO7 RN-F cable with load relief of the
appliance.
• For this reason, the backside of the appliance has
a screw with the indication "voltage compensa-
tion".
• Following the electrical connection, the action
of the protective duct, the voltage compensation
and the insulation value should be checked ac-
cording to the existing provisions of DIN VDE.
loading