Product Instructions
Operation
Testing generic power tools
Generic power tools give a "real torque":
A
A.
Torque
B.
Time (or Angle)
After installing the DJS on the PST – Pulse Static
Transducer, put the power tool on the square / hexagon
adapter of the DJS.
Testing pulse tools
There are two types of pulse tools:
• Pulse tools without shut off: they do not stop
working after the operator releases the trigger.
Pulse tools without shut off may be tested
directly on the PST – Pulse Static Transducer.
• Pulse tools with shut off: they shut off the air after
getting a preset torque level.
Pulse tools with shut off requires the DJS. If the
DJS is not used, the tightening stops after the
first or the second pulse and the test does not
give any consistent result.
After installing the DJS on the PST – Pulse Static
Transducer, put the pulse tool on the square / hexagon
adapter of the DJS.