Starting Operation
Pay attention to the mains voltage. The voltage of the power
source must match the voltage specified on the rating plate of
the power tool. Power tools marked with 120V can and should
be operated with 120V.
Preselecting the Speed
You can preselect the required speed using the Speed Pre-
selection Thumbwheel 2, even during operation. The higher
numbers indicate a high speed, while the smaller ones repre-
sent a low speed.
The Constant Electronic keeps the speed at no load and under
load virtually consistent, producing uniform performance.
The electronic soft start limits the torque when the power tool
is switched on and increases the service life of the motor.
joint compound/
plaster hardness
wall or ceiling
very soft/soft
wall or ceiling
medium hardness
ceiling
extremely hard
wall or ceiling
Dry Wall Sander Operation
Applications
internal/external
air flow setting
1
wall
1
3
1 on uneven
surfaces
3 on even surfaces
Applications
See the table "Applications" below for application informa-
tion.
Do not put the power tool down on its side. This could per-
manently warp the sanding pad.
On/Off Slide Switch
(Fig. 1)
Hold the tool with both hands while
turning on or off the tool. Torque
from the motor can cause the tool to twist.
To turn the tool "ON," slide the On/Off Slide Switch 3 forward
so that "I" appears on the switch.
To turn the tool "OFF," slide the On/Off Slide Switch 3 back-
wards so that "0" appears on the switch.
suction power
6
6
1–5
(optimum: 3)
6
1–3
-15-
sanding
speed setting
sheet grit
2–4
from P180
4–6
from P120
4–6
from P100
loading