Setting the operating modes (example: colour red)

Colour is continuously lit when activated
5 6
rd
Colour flashes when activated
5 6
rd
Colour blinks when activated
5 6
rd
Colour is unlit, independent of whether signal is activated or not.
5 6
rd

Operating modes

Each colour may be operated independently of the other colours in the operating modes continuous light, blink light or
flash light. The change of colour always takes place in the order green-yellow-red-blue-white.

Continuous light

When using only one colour, this colour is turned on continuously. When using more than one colour in the operating
mode „continuous light" each colour is turned on for 990 ms. Then the changeover to the next driven colour takes place.

Example

The colours green, red and white are in use.
grün / green / vert / verde
990 ms

Blink

When using one colour, it will be lit for 220 ms and turned off for 275 ms.
220 ms
275 ms
When using several colours, the colour blinks twice, being lit for 220 ms and turned off for 275 ms.

Flash

When using one colour, it will be lit for 55 ms and turned off for 440 ms.
55 ms
440 ms
When using several colours, the colour flashes 4 times, being lit for 55 ms and turned off for 440 ms.