The device does
not work
("ICE FULL" and
"FAULT" lights
are on)
The device does
not work
(the "FAULT"
light blinks)
The "WATER
LOW" and "ICE
FULL" indicators
blink together
or the "FAULT"
lamp flashes
quickly.
The "FAULT",
"WATER LOW"
and "ICE FULL"
lights flash
slowly.
After some time
of operation,
the "FAULT"
light flashes
quickly
The unit stops
working after 2
or more
minutes
the device is located is
below 7
C.
o
a)
Broken or not
connected sensor (or
broken circuit) for the
ice container being
full.
a)
Condenser sensor
defective or not
connected (or broken
circuit).
a)
Refrigerant leakage.
b)
Compressor is not
working.
c)
The ambient
temperature of the
environment is below
C.
7
o
a)
The Hall sensor is not
attached properly or is
damaged.
b)
Fan motor damaged.
a)
Ice agitator motor
damaged.
b)
Defective
microswitches.
c)
Damaged water
container.
d)
Water container
blocked by ice lumps.
a)
No water in the
running water supply.
operation of the device
to one with a higher
temperature.
a)
Check the connection
and the sensor - if
damaged, replace it.
a)
Check the connection
and the sensor - if
damaged, replace it.
a)
Locate the leak and seal
the system and fill it up
with the refrigerant.
b)
Damaged compressor
or ambient
temperature exceeds
C.
38
o
c)
Wait until the ambient
temperature rises or
change the place of
operation of the device
to one with a higher
temperature.
a)
Check its installation
and, if necessary,
correct it or replace it
with a new one.
b)
Replace the fan motor.
a)
Replace with a new
one.
b)
Check installation or
replace.
c)
Replace with a new
one.
d)
Remove the ice cubes
from the container.
a)
Check the running
water supply.