Simon SM34 Manual Del Usuario página 15

Cargador eléctrico
Ocultar thumbs Ver también para SM34:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Warning! For units with Bluetooth enabled, configuration must be done from the
Simon Plug&Drive APP. When Bluetooth mode is enabled, the selector is disabled.
For equipment with power modulator, see the specific table in the accessory
instruction sheet.
7. SWITCH CONFIGURATION
ON C&K SDA04
1
2
3
4
ON C&K SDA04
1
2
3
4
* It is necessary to have the following accessory installed: 0695000-030 Home dynamic
load manager for single-phase units or 0695000-040 Home dynamic load manager
for three-phase units.
ON C&K SDA04
1
2
3
4
* A device with Bluetooth or the 0695000-020 Bluetooth connection accessory must
be installed.
ON C&K SDA04
1
2
3
4
* It is necessary to have the following accessory installed: 0695000-050 Photovoltaic
single-phase dynamic load manager for single-phase units or 0695000-060
Photovoltaic three-phase dynamic load manager for three-phase units.
ON C&K SDA04
1
2
3
4
* The unit must be installed along with the Electron Manager and configured according
to the corresponding manual.
8. CLOSING THE UNIT
Press the unit cover from the bottom until it is closed.
Close:
For basic units without accessories or Bluetooth
communications, leave all in the OFF position.
SWITCH 1
ON - Home load balancing enabled
OFF - Home load balancing disabled
SWITCH 2
ON - Bluetooth communication enabled
OFF - Bluetooth communication disabled
SWITCH 3
ON - Photovoltaic power balance enabled
OFF - Photovoltaic power balance disabled
SWITCH 4
ON - Communications with Electron Manager
enabled
OFF - Communications with Electron Manager
disabled
1.
2.
Press the lowered areas
8.1. Units with T2 cable:
Lock closure:
The lid must be properly closed before inserting the lock. Closure is
achieved by joining the cover and base, not by inserting the lock.
8.2 Units with T2 base
Once the box is closed, tighten it with the two screws provided.
Choose the most suitable mechanism for closing the box, depending on
where the equipment is installed:
9. OPERATION
SM34 Residential series unit allows the charging of an electric vehicle in mode 3
using a type 2 connector. A LEDs set on the front of the unit shows its status:
Orange
Purple
Green
Blue
Blinking
blue
Blinking
blue/green
Yellow
Red
White
15
It is important to insert the lock straight as
indicated in the image. Turn clockwise to lock.
The key can only be removed if the lock is locked.
Manual (Cap)
Screwdriver lock
Turn clockwise with the help of a screwdriver to lock.
Unit locked
The unit does not have enough power to
start charging the vehicle (Units with a
manager)
The unit is receiving <7 A, so it will not
start charging the vehicle. Depending on
the vehicle model, it may not charge at
powers higher than the minimum, so it
may show purple.
Unit available
Vehicle charging
Charging complete or not started due to
lack of consumption
Waiting for the cable to be inserted or
removed
Reserved outlet
Recharging point error, not usable
Unit stopped based on schedule.
loading