A - ENGLISH
INSTALL THE BRUSHES (CYLINDRICAL SYSTEM)
1
Verify which brush or pad is appropriate for the floor surface to be cleaned.
2
Make sure the Scrub Deck (8) is in the RAISED position. Make sure the Key Switch (27) is off.
CAUTION !
Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1
Make sure the Scrub Deck is in the RAISED position. Make sure the Key Switch (27) is in the OFF position (O).
2
See Figure 2-5. Remove both side blade assemblies. NOTE: The blade assemblies are held in place by Side Blade Assembly Removal
Knobs (15). Loosen these knobs and slide the Side Blade Assemblies (BA) slightly forward and then off the Scrub Deck.
3
Loosen the Knobs (BB) on top of the Idler Assemblies (BC) and remove the assembly.
Slide the Brush (BD) into the deck housing, lift slightly, push and turn until it seats. Re-install the Idler Assemblies (BC) and Side Blade
4
Assemblies (BA).
FIGURE 2-5
BB
BC
BA
A - 16
INSTRUCTIONS FOR USE
15
Nilfisk Liberty SC60 - 56091234
BD
11/2020