Intended use of the unit also includes the requirement that
you
adhere to these instructions,
observe all other accompanying documents,
comply with national accident prevention guidelines
applicable at the place of use.
Efficiency test
In accordance with the general guidelines of the trade
association, fume extractor systems must be checked
regularly, at a minimum annually, in order to ensure that they
are fully functional (TRGS 528 BGETF). The efficiency test
also serves to check for proper functioning of the Zero Smog
4V / Zero Smog 6V / Zero Smog 2T solder fume extractor
systems.
Technical Data
Solder fume extraction
Dimensions L x W x H
Weight
Mains supply voltage
Electrical power rating
Fuse
Maximum vacuum
Maximum quantity supplied
Noise emission level
Pre filter Stage 1
Combined filter
Stage 2; 3
RS232 port
USB port
Zero Smog 4V
320 x 320 x 395 mm
19 kg
T0053660699:
230 V / 50 Hz
T0053660299:
120 V / 60 Hz
275 VA
T1, 6A
2.700 Pa
230 m³/h
48 dB(A)
pre filter mat class F7
Particle filterH13 + Gas filter (50% Activated carbon + 50 % Potassium Permanganate)
All system functions can be operated and remotely monitored via the RS232 port.
The USB port can be used to load firmware updates, run efficiency tests and log data.
Do not leave the USB medium inserted for longer than 2 minutes. After this time expires,
the USB module will switch off automatically.
User groups
Due to differing degrees of risk and potential hazards, seve-
ral work steps may only be performed by trained experts.
Work step
Installation of complex
pipe systems with multiple
extractor arms connectedI
Replacing electrical repla-
cement parts
Specification of mainte-
nance intervals
Installation of complex
pipe systems with multiple
extractor arms connected
Replacing electrical repla-
cement parts
Zero Smog 6V
450 x 450 x 650 mm
40 kg
T0053666699:
230 V / 50 Hz
T0053666299:
120 V / 60 Hz
460 VA
T3, 15A
2.800 Pa
615 m³/h
51 dB(A)
ENGLISH
User groups
Specialist personnel with
technical training
Electricians
Non-specialists
Technical trainees under the
guidance and supervision of a
trained expert
Zero Smog 20T
450 x 450 x 695 mm
45 kg
T0053670699:
230 V / 50 Hz
530 VA
T3, 15A
10.000 Pa
100 m
/h
3
51 dB(A)
EN