Safety Notes
 Gloves	should	be	worn	during	installation	to	prevent	
	
crushing	and	cutting	injuries.
 The	product	may	only	be	used	for	bathing,	hygienic	
	
and	body	cleaning	purposes.
 The	hot	and	cold	supplies	must	be	of	equal	pressures.
	
Installation Instructions
•	Prior	to	installation,	inspect	the	product	for	transport	
damages.	After	it	has	been	installed,	no	transport	or	
surface	damage	will	be	honoured.
•	The	pipes	and	the	fixture	must	be	installed,	flushed	
and	tested	as	per	the	applicable	standards.
•	The	plumbing	codes	applicable	in	the	respective	
countries	must	be	observed.
Technical Data
Operating	pressure:	
Recommended	operating	pressure:	
Test	pressure:	
	
Hot	water	temperature:	
Thermal	disinfection:	
The	product	is	exclusively	designed	for	drinking	water!
Fault
Mixer	stiff
Mixer	dripping
Hot	water	temperature	too	low,	no	
cold	water.	Instantaneous	water	
heater	starts	up	when	cold	water	is	
selected.
4
max.	1	MPa	
0,1	-	0,5	MPa	
1,6	MPa	
(1	MPa	=	10	bar	=	147	PSI)	
max.	60°C	
70°C	/	4	min
Cause
-	Cartridge	defective,	calcified
-	Cartridge	defective
-	Hot	water	limiter	incorrectly	set
-	Crossflow
Assembly (see	page	35)
English
Symbol description
Do	not	use	silicone	containing	acetic	acid!
Adjustment (see	page	37)
To	adjust	the	hot	water	limiter.	Using	a	hot	water	limiter	in	
combination	with	a	continuous	flow	water	heater	is	not	
recommended.
Dimensions (see	page	38)
Flow diagram (see	page	38)
	
free	flow
Spare parts (see	page	39)
XXX	 =	 Colors	
000	=	 Chrome	Plated	
340	=	 Brushed	Black	Chrome
Cleaning (see	page	41)
Operation (see	page	40)
Hansgrohe	recommends	not	to	use	as	drinking	water	the	
first	half	liter	of	water	drawn	in	the	morning	or	after	a	
prolonged	period	of	non-use.
Test certificate (see	page	42)
Remedy
-	Exchange	cartridge
-	Exchange	cartridge
-	Set	hot	water	limiter