<1> Can be used freely as long as manufacturer-specific PROFIdrive-telegram 220 is not selected [2425.5], [2428.5].
1
2
DO: DC_CTRL
Sequence control - Missing enable signals, logic operations
Bit No.
Missing enable signal
0
1 = OFF1 enable missing
1
1 = OFF2 enable missing
2
1 = OFF3 enable missing
3
1 = Operation enable missing
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
1 = Ramp-function generator enable missing
11
1 = Ramp-function generator start missing
12
1 = Setpoint enable missing
13
Reserved
14
Reserved
15
Reserved
16
1 = OFF1 enable internal missing
17
1 = OFF2 enable internal missing
18
1 = OFF3 enable internal missing
19
1 = Pulse enable internal missing
20
Reserved
21
Reserved
22
Reserved
23
Reserved
24
Reserved
25
Reserved
26
1 = Drive inactive or not operational
27
Reserved
28
1 = Brake open missing
29
Reserved
30
1 = Speed controller inhibited
31
1 = Jog setpoint active
3
4
Missing enable sig
r0046
(r0898.0 = 0)
r0046.0
(r0898.1 = 0)
r0046.1
(r0898.2 = 0)
r0046.2
(r0898.3 = 0)
r0046.3
(r0898.4 = 0)
r0046.10
(r0898.5 = 0)
r0046.11
(r0898.6 = 0)
r0046.12
(r50000 = 7.2
7.6)
r0046.16
(r50000 = 10)
r0046.17
(r50000 = 9.3)
r0046.18
(r50000 = 1.2
1.5)
r0046.19
(r50000 1.0)
r0046.26
(r0898.14 = 0)
r0046.28
(r0898.12 = 0)
r0046.30
(r0898.8 / r0898.9 = 0)
r0046.31
5
6
fp_2655_13_eng.vsd
14.11.16 V01.05.00
16000 μs
Logic operations
AND operation <1>
AND input 1
p2810[1]
AND result
(0)
r2811
AND input 2
&
r2811.0
p2810[0]
(0)
OR operation <1>
OR input 1
p2816[1]
OR result
(0)
r2817
OR input 2
1
r2817.0
p2816[0]
(0)
7
8
Function diagram
- 2655 -
SINAMICS DCM