Fracarro HEAD LINE SIG7900 Instrucciones De Uso página 14

Módulo de interconexión
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Fig. 5
Fig. 6
Fig. 7
The TPE recognises the new module and needs its address. Using the "arrow up" & "arrow down"
buttons on the TPE the number assigned can be modifi ed and then push the V button to confi rm.
It is recommended that the fi rst row of the headend is set as row 1, the second as row 2 and so
on up to the 15th.
Important: It is not possible to assign the same number to two or more rows.
The row is allocated a number so that each module can have an individual address consisting of
2 numbers, the fi rst indicates the row number, the second the position of the module within the
row (see fi g.15).
Repeat this operation for each mounting rack installed.
Connect the mains cable supplied in the
rack box to the interconnection module
(see fi g. 5 and 6).
After a few seconds the display will light
up and show "00". This means there is no
set address on the interconnection modu-
le. Connect the TPE to the interconnection
module to be programmed using RJ45IN
(see fi g.7).