Wesco WS5047 Manual Del Usuario página 14

Idiomas disponibles

Idiomas disponibles

of the circle to be cut. Drive in a nail less than 6mm in
diameter to secure the extension guide. Pivot the trimmer
around the nail in clockwise direction. (See Fig. L)
Replacing the carbon brushes (See Fig. M1,
M2)
Remove and check the carbon brushes regularly. Replace
when they wear down to the limit mark. (See Fig. M1)
Remove the carbon brush cover with a screwdriver and get
out the worn carbon brushes. (See Fig. M2) Insert the new
ones and then secure the brush holder caps.
Use only identical carbon brushes. Make sure to replace
both of them at the same time. Keep the carbon brushes
clean.
MAINTENANCE
Remove the plug from the socket before
carrying out any adjustment, servicing or
maintenance.
Your power tool requires no additional lubrication or
maintenance. There are no user serviceable parts in your
power tool. Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always store
your power tool in a dry place. Keep the motor ventilation
slots clean. Keep all working controls free of dust.
Occasionally you may see sparks through the ventilation
slots. This is normal and will not damage your power tool.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
EN
14
loading

Este manual también es adecuado para:

Ws5047u