Cardin Elettronica S504 Serie Manual Del Usuario página 14

Ocultar thumbs Ver también para S504 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Indications on the receivers
Red Led L1 - user management
- Flashing slowly: memorising a single user
- Flashing rapidly: cancelling a single user
- Continuously lit: memory full
SINGLE CHANNEL RECEIVER SYSTEM MANAGEMENT OPERATIONS (RVQ504C1 / RVQ508C1)
Attention! Before memorising the transmitters for the first time remember to cancel the entire memory content.
• Memorizing a channel code
1. Press and hold down button "P1", LED "L1" will flash slowly.
2. At the same activate the transmitter channel to be memorised, "L1" will remain lit for 2 seconds
indicating that the channel has been memorised; if the LED keeps flashing slowly the channel was
already memorised. Only one channel can be memorised at a time. To insert another channel repeat
points 1 and 2 after having released the button. When the code memory is complete (1000 transmitters
memorised) you may only memorise a new transmitter after you have completely cancelled an existing
transmitter or after cancelling the entire memory content.
• Deleting a channel code (via an associated transmitter)
1. Press the button "P1" twice and hold down after pressing the second time: LED "L1" will flash at brief
intervals.
2. Activate the transmitter channel to be cancelled, "L1" will remain lit for 2 seconds indicating that the
channel has been cancelled;.
To cancel another channel repeat points 1 and 2 after having released the button.
• Deleting the entire code memory content (users)
-
Press "P1" three and hold down after pressing the third time. During the cancellation procedure (3-4
seconds) LED "L1" remains lit. After cancellation the LED will flash 3 times; at this point release the
button.
Green Led L2 (only RVQ504C4 / RVQ508C4)
- Appliance "STATUS" LED
- Continuously lit: power on
- Flashing: no memory module present
14
loading

Este manual también es adecuado para:

S508 serie