Transmitters
The transmitter is pre-coded and is fitted with an integrated circuit which is programmed in the factory
with a unique identification number. All the code parameters are contained in this integrated circuit. The
transmitter has an automatic shut down mechanism which cuts in after at least 20 seconds of continuous
use (this limits battery consumption).
Key block function
• A key block function has been added to protect the appliance from
accidental activation;
- to activate the function press and hold down "MR" for 8 seconds until
the orange led starts flashing, at this point to activate a command you
will need to press the required key three times consecutively;
- to reset the function to standard operation, press and hold down "MR"
for 8 seconds until the orange led starts flashing.
Transceivers
The transceivers are fitted with a buzzer which sounds to confirm the execution of the command and red
and green led lighting indicates the status of the relay (green = open, red = closed).
FASTENING THE OUTDOOR RECEIVER IP55 (fig. 4)
Open the four fastening holes as shown in the drawing using a screwdriver of similar tool. Trace the
four wall fastening points using the container as a template and then drill the holes (det. 3-4). Fasten
the container using four self-tapping screws M4,8 (det. 5). Once the container has been fastened insert
the screw covers. Remove the cable clamp covers and affix the two cable clamps as shown in detail 6.
Receiver electrical connection (fig. 5/6)
RVQ504C1 / RVQ508C1 are fitted with a 6-way terminal board and have a 230Vac electrical connection
between binding posts 1-2.
RVQ504C4 / RVQ508C4 are fitted with an 18-way terminal board and have a 230Vac electrical
connection between binding posts 2-3.
12