Wesco WS8911K Manual Del Usuario página 14

Idiomas disponibles

Idiomas disponibles

LASER PROJECTION
DIAGRAM
One horizontal laser line;
Four vertical laser lines;
One plumbing dot (See Fig. A)
PRODUCT FEATURES
1. This series of products adopt a damping compensation
system, which can be adjusted to the center of the bubble to
ensure fast leveling and save time.
2. Precision dot to the ground precisely positions the
machine.
3. The 360-degree swivel base with fine-tuning buttons
ensures the machine quickly finds the target.
4. The automatic locking device automatically locks the
instrument when it is turned off and automatically unlocks
when it is turned on.
5. An optional receiver is available to increase the working
range to 30m.
OPERATING
INSTRUCTIONS
1. Charging (See Fig. B)
The product works with a lithium-ion battery. Please use the
original charging device.
WARNING! The instrument is partially charged
before shipment, so please fully charge the battery
before first use.
WARNING! Recharge is not recommended for
more than 24 hours after each use.
1) Plug charger plug into a suitable power outlet and
afterwards plug your tool into the battery charger (the
battery should installed on the tool).
2) The charging Indicator light on the charger will turn red
during charging. When charging is done, it will turn green.
3) Unplug the charging plug from the wall socket and then
remove the tool from the battery charger.
WARNING! Do not charge at extremely high or
low temperatures. Do not charge at a temperature
below 0°, otherwise the battery life will be reduced. The tool
and power adapter will heat slightly when charging.
CAUTION! Please charge and discharge the
battery periodically to extend the service life of
battery when it has not been used for long time.
CAUTION! The battery equipped has been tested
by our strict internal quality control process and
inspection standards. Do not disassemble the battery or
replace with other brands, so as to avoid possible dangers
such as electric shock, explosion and burn. The battery
14
equipped enjoys the quality assurance. Any repair or
disassemble required on battery should be performed only
by authorized service personnel or after-sales department.
CAUTION! Some attenuation will happen normally
in the Li-ion battery after long time working such
as two years. Any questions, please contact local qualified
service center or after-sales department timely.
2. Turn on/off (See Fig. C)
1)
Turn the switch knob to the "ON" position. The tool is
turned on and gets into leveling mode;
2) Turn the switch knob to the "OFF" position. The tool is
turned off.
3. Auto-leveling mode
1)
Place the tool naturally, and turn it on. The tool will
automatically level when it is tilted 3°. If the leveling
range is exceeded, the buzzer will flash alarm.
2) If auto-leveling is always not possible, it means the
surface on which the tool stands deviates by more than
auto-leveling range 3° from the horizontal plane. Please
adjust the tilt angle with the adjustable bracket based
on the deviation direction of auxiliary bubble, so as to
place the tool in a position close to level (≤3° from the
horizontal plane).
4. Turn on/off the horizontal laser (See Fig. D)
Press the "H" key to turn on the horizontal laser. The laser
lights up green. Press the key again to turn off the horizontal
laser.
5. Turn on/off the vertical laser (See Fig. D)
Press the "V" key once to turn on two vertical lasers; press
the "V" key twice to turn on four vertical lasers; press it
again to turn off the vertical laser. All the horizontal lasers
light up green. Press the key again to turn off the vertical
laser.
The plumbing dot lights up only when the vertical laser is on.
6. Outdoor operating mode (See Fig. D)
Short press the" " key to enter into the outdoor operating
mode which needs to used with the laser receiver (not
included). Press the " " key again to close the outdoor
operating mode.
7. Working with the tripod (not included)
The machine can be used with a 5/8'' tripod.
EN