IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR ELECTRIC SHOCK
WARNING – This manual contains important instructions for Model EVC-L2-S48-18 that shall
be followed during installation, operation and maintenance of the unit. Installation requires
knowledge of electrical systems, if not qualified, do not attempt installation and contact a
qualified electrician.
a)
Read all the instructions before using this product.
b)
This device should be supervised when used around children.
c)
Do not put fingers into the electric vehicle connector.
d)
Do not use this product if the flexible power cord or EV cable is frayed, has broken
insulation, or any other signs of damage.
e)
Do not use this product if the enclosure or the EV connector is broken, cracked, open, or
shows any other indication of damage.
f)
CAUTION - To reduce the risk of fire, connect only to a circuit provided branch circuit over-
current protection in accordance with the ANSI / NFPA 70 National Electrical Code (USA),
CSA C22.1–15 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical
installations (utility) (Mexico).
Charger (A)
Circuit Breaker (A)
g)
To avoid a risk of fire or electric shock, do not use this device with an extension cord.
h)
Risk of electric shock. Other than the charging cable, charger contains no field serviceable
parts. Do not remove cover or attempt to open the enclosure unless a qualified electrician.
i)
Not for use in environments where explosive or corrosive gases are present
j)
WARNING - Turn off power at the circuit breaker before installing
k)
GROUNDING INSTRUCTIONS - This product must be grounded. If it should malfunction
or break down, grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This product is equipped with a cord having an equipment
grounding conductor and a grounding plug. The plug must be plugged into an appropriate
outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
l)
WARNING – Improper connection of the equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as
to whether the product is properly grounded. Do not modify the plug provided with the
product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Circuit Breaker Requirement
24
30
www.breez-EV.com 847-380-3540
32
40
40
50
48
60