Energy saving
29
mode on/off
Battery
30
equalization
Battery
equalization
31
voltage
Battery
33
equalization time
Battery
equalization
34
period
Equalization
35
interval
User manual
Power saving mode
disabled (default)
Power saving mode
enabled
Battery
equalization
enabled
Options available for 24V model
The range is from 24.0V to 28.8V
Each click increases the value by 0.1V.
60min(default)
120 min(default)
30 days (default) The interval that can be
28
If this function is disabled, it
does not matter if the load is
low or high, the output state
of the inverter will not be
affected.
If this function is activated,
the inverter output will be
stopped when the connected
load is low or cannot be
detected.
Battery equalization disabled
(default)
The interval that can
be set is between 5 min
and 900 min. Each click
increases the value by 5
min.
The interval that can
be set is between 5 min
and 900 min. Each click
increases the value by 5
min.
set is between 0 and 90
days. Each click increases
the value by 1 day.