18
Floating load
Low DC voltage
19
setting (cut off
voltage)
Battery discharge
voltage interruption
20
when power from
the public grid is
available
Interruption of the
battery charging
21
voltage when the
power from the
Utility is available
22
Display interface
User manual
24V model default settings: 27.0V
If "User-Defined" is selected in program 14, this
program can be set. The range that can be set is
between 24.0V and 29.2V for 24Vdc. Each click
increases the value by 0.1V
24V model default settings: 20.4V
If "User-Defined" is selected in program 14, this
program can be set. The range that can be set is
between 20.0V and 24.0V for the 24Vdc model.
Each click increases the value by 0.1V.
Options for the 24V model:
23V (default)
Options for the 24V model:
27.0V (default)
26
Range 22.0V - 29.0V
Each click increases the
value by 0.1V
Range 22.0V - 29.0V.
Each click increases the
value by 0.1V
The screen will display the
main interface
The last page used by the
user is displayed on the
screen