Kongskilde MultiCutter MCC GR250X Manual Operativo página 5

Idiomas disponibles
  • ES

Idiomas disponibles

Adjustment of the fixed knife:
The knives are adjusted by the manufacturer – i.e. this instruction shall only be used after repairs.
1) Check that the screws (pos. 3) are tightened.
2) The screws (pos. 2) are turned till "hand tight".
3) The screws (pos. 4) are tightened sufficiently so that the fixed knife (pos. 1) is just touching the
rotor blades. During tightening the rotor is turned manually and it must be checked that the
resistance against turning is equal for all rotor knives. Rotor knives must never touch each
other while adjusting.
4) The screws (pos. 5) are tightened, and the position of the knives is checked by feeding a thin
piece of paper down between the knives, while the rotor is turned manually. It must be
checked that each rotor knife is cutting over its total length. The screws (Pos. 2) are tightened,
and the check is repeated. If the knives are not cutting evenly adjustment is made by means of
screws (pos. 4 and 5).
5) The blower is turned off at the electric control unit and the Granulator is turned on. If the
Granulator is making noise the screws (pos. 4) are loosened and the screws (pos. 5) are
tightened until the noise stops. To avoid damaging the knives adjustment, while running, must
be done with extreme care and therefore the screws (pos. 2) must never be loosened.
Manual_GR250X_180123_EN
EN
3
loading