Technical Specifications; Electrical Wiring - Buffalo CD474 Manual De Instrucciones

Grill de contacto
Ocultar thumbs Ver también para CD474:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Telephone Helpline: 0845 146 2887
Fault
Power indicator light comes
on but product does not
heat up
Product slow to heat up

Technical Specifications

Code
Voltage
CD474
230V 50Hz
DM902
230V 50Hz
DM903
230V 50Hz

Electrical Wiring

This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard
The plug is to be connected to a suitable mains socket
The appliance is wired as follows:
• Live wire (coloured brown) to terminal marked L
• Neutral wire (coloured blue) to terminal marked N
• Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit
If in doubt, consult a qualified electrician
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible
Probable Cause
Faulty element
Faulty thermostat
Thermostat set incorrectly
Cooking surface not cleaned
Faulty element
Power
Current
Watts
1500W
6.5A
2900W
12.6A
2200W
9.5A
Call your BUFFALO agent or qualified
electrical technician
Call your BUFFALO agent or qualified
electrical technician
Check thermostat setting
Clean cooking surface as instructions
Call your BUFFALO agent or qualified
electrical technician
Plate Type
Top
Bottom
Rib
Rib
210 x 290 x 320
Rib
Rib
210 x 540 x 320
Rib
Rib
210 x
Action Required
Dimensions
Weight Kgs
h x w x d (mm)
14.5kgs
27.0kgs
x 320
19.0kgs
380
UK
5
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dm902Dm903