Sagi KP12G1M Instrucciones Originales página 85

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 96
All of the units have the following control panel installed:
1
2
CONTROL PANNELS
7 8 9
3
4
ON/SBY key
Press this key for 3 seconds and release it as the display shows
the [Sby] to set the appliance to the stand-by mode
(Backlighting activated).
When holding device in stand-by pressed [the display shows
Sby], the controller turns on (Backlighting deactivated).
ENTER key
Press and release this key to check/change the appliance
temperature setpoint; during operations the above mentioned
backlighting is flashing.
UP and DOWN keys
These keys allow to increase or decrease the value of the
parameter to be changed (the backlighting is flashing during
these operations).
Pressed and released enable the visualisation of the minimum
and maximum temperatures recorded (if available) and any
active alarms (the backlighting is flashing during these
operations)
The
button, held down for a period exceeding 3 seconds,
allows the modification of the chamber humidity settings
(backlighting flashing).
Pressed at the same time for a time greater than 3 seconds
enables the selection of the keyboard lock or entry into
parameter configuration by way of the confirmation with the
button.
DEFROST key
Pressed for a time greater than 3 seconds activates /
deactivates the manual defrost (the backlighting is activated
during these operations)
LIGHT key
Pushed and released allows the activation or the deactivation of
the unit's interior illumination (backlighting ON with light ON,
backlighting OFF with light OFF), independent of the status in
which the
button might be.
5
6
15
POS
DESCRIPTION
1
ON/SBY key
2
ENTER key
3
DOWN key
4
UP key
5
DEFROST key
6
LIGHT key
7
DEFROST ICON
8
FAN ICON
9
COMPRESSOR ICON
loading

Productos relacionados para Sagi KP12G1M

Este manual también es adecuado para:

Kp12g2mP12g1mP12g2m