Functions For Wash Fittings And Urinals - Franke ZAQUA091 Instrucciones De Montaje Y Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7.2
When a remote command is accepted, the LED in the sensor (d) of the fitting
flashes. The flashing intervals are described in the relevant functional description.
• Each time that a remote command is accepted, the fitting remains in remote
control mode for a further 60s.
• This does not apply for cleaning switch-off.
A flashing LED in the sensor (d) of the fitting is only visible at sensor height on the
Protronic-S series of products.
8.

Functions for Wash Fittings and Urinals

Test Mode = simulation without water
In Test Mode, the sensor range can be tested and adjusted without flowing water.
8.1
Press the TEST key.
• Test mode is activated.
• The LED in the sensor of the fitting flashes:
– 4 × short, break, 4 × short
• The LED in the sensor of the fitting lights up when a hand or object is detected.
8.2
Adjust the range.
8.3
Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
• The LED in the sensor of the fitting flashes:
– 4 × short, break, 4 × short
• The LED in the sensor of the fitting is off.
Setting the Range
8.4
Use the + and – keys (
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment by one step
– 2 x long when the respective end setting is reached
) to adjust the range in individual steps.