The process of thermal disinfection
• Start thermal disinfection
• Start delay
The solenoid valve opens only after the set start delay.
Hot water starts to flow 10s after the start of thermal disinfection.
• Treatment time
Hot water flows for 2 min.
After 2 min, the water starts flowing in a pulsating mode for the remainder of the
set time (exposure phase).
• Safety window
During this time the water in the circulation line is to cool down to the preset
temperature.
• Cooling down phase
The remainder of the hot water in the fitting is flushed out.
Setting the parameters
The parameters for exposure time and cooling time cannot be set independently of
each other.
10.15 Press and hold the RESET key.
10.16 Additionally press the
• The LED flashes 4 × briefly.
• The fitting switches to Normal Mode.
• The LED flashes twice with a 1s interval.
10.17 Use keys + and - (
Cooling time
Exposure time
By default, the parameter is set to code 7.
• The LED in the sensor confirms the code that was entered
– LED flashes briefly = unit digit
– LED flashes long = tens digit
Example: The LED flashes 2 x long and 1 x short = Code 21 was set. The exposure
time is 3 min. The cooling time is 60s
14
OFF key within 2s.
) to set the code for the desired pair of parameters.
0
3 min
1
5 min
2
10 min
3
15 min
4
20 min
5
10s
20s
30s
6
11
16
7
12
17
8
13
18
9
14
19
10
15
20
60s
21
22
23
24
25