Setting the range for the body reflection function
☞
When the flow duration is set to 3s, the fitting is in the Body Reflection Mode.
The range can be set in 24 steps.
– Range 1: 18 cm
– Range 24: about 50 cm
11.2 Use the + and – keys (
• The LED in the sensor confirms the range that was entered
– LED flashes briefly = unit digit
– LED flashes long = tens digit
Switching off the fitting
11.3 Press the
• The LED in the sensor flashes 4 × briefly.
• The fitting has been switched off.
• The LED in the sensor flashes with 3s intervals
Switching on the fitting
11.4 Press the
• The LED in the sensor flashes 2 × long.
• The fitting has been switched on.
• The LED in the sensor does not flash.
Adjusting flow duration
11.5 Use the + and – keys (
• The LED in the sensor of the fitting flashes:
– 1 x short = 3 s
– 2 x short = 10 s
– 3 x short = 20 s
– 4 x short = 30 s
– 5 x short = 40 s
– 6 x short = 50 s
☞
The flow duration is factory-set to 30s.
16
) to adjust the range in individual steps.
OFF key.
OFF key.
) to adjust the flow duration in individual steps.
– 7 x short = 1 mins
– 8 x short = 2 min
– 9 x short = 3 min
– 1 x long = 4 min
– 1 x long , 1 x short = 5 min