Franke ZAQUA091 Instrucciones De Montaje Y Uso página 16

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Setting the range for the body reflection function
When the flow duration is set to 3s, the fitting is in the Body Reflection Mode.
The range can be set in 24 steps.
– Range 1: 18 cm
– Range 24: about 50 cm
11.2 Use the + and – keys (
• The LED in the sensor confirms the range that was entered
– LED flashes briefly = unit digit
– LED flashes long = tens digit
Switching off the fitting
11.3 Press the
• The LED in the sensor flashes 4 × briefly.
• The fitting has been switched off.
• The LED in the sensor flashes with 3s intervals
Switching on the fitting
11.4 Press the
• The LED in the sensor flashes 2 × long.
• The fitting has been switched on.
• The LED in the sensor does not flash.
Adjusting flow duration
11.5 Use the + and – keys (
• The LED in the sensor of the fitting flashes:
– 1 x short = 3 s
– 2 x short = 10 s
– 3 x short = 20 s
– 4 x short = 30 s
– 5 x short = 40 s
– 6 x short = 50 s
The flow duration is factory-set to 30s.
16
) to adjust the range in individual steps.
OFF key.
OFF key.
) to adjust the flow duration in individual steps.
– 7 x short = 1 mins
– 8 x short = 2 min
– 9 x short = 3 min
– 1 x long = 4 min
– 1 x long , 1 x short = 5 min