6. APPLICATION RANGE:
When using the generator, make sure the total load is within rated output of a
generator. Otherwise, generator damage may occur.
AC
Power factor
3500i
~ 3000W
TIP:
• "~"means below.
• Application wattage indicates when each device is used by itself.
• The simultaneous usage of AC and DC power is possible but total wattage should
not exceed the rated output.
EX:
Generator rated output
Frequency
AC
DC
The overload indicator light comes on when total wattage exceeds the application
range.
NOTICE
•
Do not overload. The total load of all electrical appliances must not exceed the
supply range of the generator. Overloading will damage the generator.
•
When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer based equipment or battery chargers, keep the
generator at a sufficient distance away to prevent electricalinterference from the
engine. Also ensure that electrical noise from the engine does not interfere with
any other electrical devices located near the generator.
•
If the generator is to supply medical equipment, advice should first be obtained
from the manufacturer, a medical professional or hospital.
•
Some electrical appliances or general-purpose electric motors have high starting
currents, and cannot therefore be used, even if they lie within the supply ranges
given in the above table. Consult the equipment manufacturer for further advice.
62
1
0.8-0.95
~ 2400W
3000VA
Power factor
1.0
~ 3000W
0.8
~ 2400W
96W(12V/8A)
- -
0.4-0.75
Efficiency 0.85
~ 1200W
DC
Rated voltage 12V
Rated current 8A