Klarstein BOLEA Manual Del Usuario página 25

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Minimum distances
Ceramic glass rings/heating plates
Gas cooker
Coal/oil/wood stove
Installation with exhaust air
Note: Observe the safety instructions for operating the unit when the air is
discharged to the outside. If the cooker hood is in operation at the same time
as an appliance that draws its energy from a source other than electricity, the
negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar).
Installation with convection function
If you do not have an outdoor extractor, you do not need an exhaust air pipe. The
installation corresponds to installation with external ventilation.
Important notes for the installation of exhaust air pipes
The following rules must be strictly observed to guarantee optimum air extraction:
Failure to follow these instructions will reduce the performance and increase the
noise level of the cooker hood.
Lay the exhaust pipe as short and straight as possible.
Do not use a smaller exhaust pipe and do not constrict it.
When using flexible pipes, the pipe must always be installed tightly in order to
minimise pressure loss.
All installation work must only be carried out by a qualified electrician or a
qualified person.
Do not connect the hood's exhaust pipe to an existing ventilation system that
is being used for another device, such as a fireplace.
The angle of the bend of the exhaust air pipe should not be less than 120°.
Align the pipe horizontally. Alternatively, the pipe should go up from the
starting point and be led to an outer wall.
After installation, make sure that the cooker hood is horizontal in order to
prevent grease from collecting on one side.
Make sure that the exhaust duct selected for installation complies with the
relevant standards and is fire resistant.
65 cm
75 cm
85 cm
EN
25
Tabla de contenido
loading

Este manual también es adecuado para:

100412231004122410041225

Tabla de contenido