Fault
Insufficient water
handshower delivering insufficient water
Temperature regulation not possible
Shower or spout dripping
Thermostat cartridge stiff
QU ICK
C L EAN
Cleaning the hand and head shower
The QuickClean cleaning function only
needs a small manual rub over to remove
the lime scale from the spray channels.
Cleaning recommendation see on enclosed brochure:
Cause
Filters at the isolation valves blocked.
Shower filter seal dirty
Temperature regulator dirty or calcified
at new installation: connection hoses con-
nected the wrong way round.
Dirt or sedimentation on valve seat, shut-off
unit damaged
Thermostat cartridge dirty or calcified
1
2
TrOuBLE ShOTING/ CLEaNING INSTruCTION
Remedy
Clean the filters
Clean filter seal between shower and hose
Clean temperature regulator, exchange if
necessary
install the hoses the correct way round.
Clean or exchange shut-off unit
Clean thermostat cartridge, exchange if
necessary