Flush Installation

A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a 1/4" (6 mm) reveal on the top, a
1/4" (6 mm) reveal on the sides, and a 1/8" (3 mm) reveal on the
bottom of the wall oven.
The front face of the cleats and platform will be visible and should
be treated as a finished surface.
A
B
C
D
E
F
G
H
Front View
27" (68.6 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 27
1
/
" (69.2 cm) minimum
4
width of flush inset cutout
C. 25
7
/
" (65.7 cm) minimum
8
width of opening
D. 43
1
/
" (109.5 cm) minimum
2
height of flush inset cutout
E. 42
1
/
" (107.9 cm)
2
recommended cutout height
F.
11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I.
4
5
/
" — 19
1
/
" (11.7 - 48.9 cm)
8
4
bottom of cutout to floor
J.
25" (63.5 cm) minimum depth
of cutout
* Cleats and spacers must be recessed 1
front of the cabinet.
F
G
J
H
I
Side View
30" (76.2 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 30
1
/
" (76.8 cm) minimum
4
width of flush inset cutout
C. 28
7
/
" (73.3 cm) minimum
8
width of opening
D. 43
1
/
" (109.5 cm) minimum
8
height of flush inset cutout
E. 42
1
/
" (107.9 cm)
2
recommended cutout height
F.
11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I.
4
5
/
" — 19
1
/
" (11.7 - 48.9 cm)
8
4
bottom of cutout to floor
J.
25" (63.5 cm) minimum depth
of cutout
3
/
" (3.5 cm) from the
8
A
C
D
27" (68.6 cm) models
A. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
1
/
" (3.5 cm) recess from front
2
of cabinet
D. 11/16" (1.7 cm) side cleat*
* Cleats and spacers must be recessed 1
front of the cabinet.

Electrical Requirements

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local
codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A
B
D
Top View
30" (76.2 cm) models
A. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
1
/
" (3.5 cm) recess from front
2
of cabinet
D. 11/16" (1.7 cm) side cleat*
3
/
" (3.5 cm) from the
8
9
Tabla de contenido
loading

Este manual también es adecuado para:

30

Tabla de contenido