Sonesse 40 RS485
2.2.Wiring
2.2.1.Power wiring
PRECAUTION
• Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
• Secure cables to prevent any contact with moving parts.
• The drive cable cannot be removed. If it is damaged, return the drive to the After-Sales department.
• Leave the drive power supply cable accessible: it must be easily replaceable.
• Connection must be done in a junction box.
1] Switch off the power supply.
2] Connect the drive according to the information in the table below:
120 V 〜 50 Hz
220 V 〜 60 Hz
230 V 〜 50 Hz
2.2.2.Data wiring
CAUTION
• There is a RJ45 female to female coupler provided with the drive to add easily an
extension cable.
• Make sure the data cable is not pinched or damaged during the installation of the
drive/tube onto the end bracket.
Connect the data cable to the drive according to the information in the tables below.
1: + RS485
2: - RS485
3: Not connected**
4: Power out *
* The LSU Power Out characteristics comply with the following voltage and current characteristics: 8 V min – 50 mA max.
** If connected, the drive can be damaged.
NOTICE
The wiring guide is available for download at https://www.somfy.com/projects/downloads
©
Copyright
2021 SOMFY ACTIVITES SA. All rights reserved.
Neutral (N)
White
Blue
Blue
5: Not connected**
6: Not connected**
7: Not connected**
8: GND
Live (L)
Black
Brown
Brown
OFF
N
L
8
1
7
2
6
3
5
4
EN
5