Make Electrical Connection Inside Range Hood Between In-Line Blower System And Range Hood - ELICA KIT0179549 Guía De Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Make Electrical Connection Inside Range Hood Between In-Line Blower System and Range Hood

1
With the range hood mounted (see the range hood
installation instructions), locate the wiring cable connector
inside the range hood.
B
MODELS ETR134S1, ETR146SS, EAR134S4, EAR140S4 and
A
A. Range Hood Junction Box
B. Range Hood knockout for Wire Connector Assembly
C. Wire Connector Assembly (provided in the In-Line Blower Kit)
D. Power Supply Wiring Conduit
MODELS ELN136S2, ELN142S2, ELN148SS,
A. Range Hood Junction Box
B. Range Hood knockout for Wire Connector Assembly
C. Wire Connector Assembly (provided in the External Blower Kit)
D. Power Supply Wiring Conduit
MODELS ECL136S4, ECL142S4 and ECL148S4
A. Range Hood Junction Box
B. Range Hood knockout for Wire Connector Assembly
C. Wire Connector Assembly (provided in the External Blower Kit)
D. Power Supply Wiring Conduit
14
D
C
EAR146S4
ELI136S2 and ELI142S2
2 Connect the 6 wire connector assembly supplied with the
in-line blower motor system to the mating connector from
the range hood.
A
B
A. Wire Connector Assembly (provided in the In-Line Blower Kit)
B. Hood Insert Blower Connector
3 Install UL listed or CSA approved strain reliefs. Run through
the strain reliefs the 6 wire connector and the In-Line
Blower wiring conduit (not incluided leaving enough wire
length to make the wiring connections.
4 Tighten the strain relief screws.
5 Connect the wires from the 6- wire connector assembly to
the wires from the wiring conduit inside the range hood
terminal box.
6 NOTE: Connect the green (or green/yellow) ground wire
from the wiring conduit to the green (or bare) ground wire
from the home power supply and to the and to the green/
yellow ground wire from the 6-wire connector assembly
(H) using UL listed wire connectors (see the "Make
Electrical Power Supply Connections to Range Hood"
section in the range hood installation instructions).
B
A
A. Strain relief
F. Blue wires
B. UL listed wire connectors
G. Gray wires
C. Black wires
H. Green (or yellow/ green) and green / yellow wires
D. White wires
I. Motor electrical plug cable
E. Red wires
7 Connect the home power supply wiring to the range hood
following the instructions that are supplied with the range
hood.
8 Reinstall the range hood terminal box cover.
9 Reconnect power.
C
D
E
F
G
H
I
Tabla de contenido
loading

Tabla de contenido