Installation And Electrical Connection - Baxi Quantum MINI Instrucciones De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4 Installation and electrical connection

4.1
Installation
DANGER: Before starting work, make sure that the
pump is disconnected from the power supply.
Installation site
• Provide a weatherproof, frost-free, dust-free, and well-
ventilated room for the installation.
Choose an easily accessible installation site.
• Prepare the installation site so that the pump can be
installed without being subjected to mechanical stresses.
If necessary, support or secure piping on both sides of the
pump.
NOTICE: Provide shut-off devices upstream and down-
stream of the pump to facilitate potential future pump
replacement. Perform the installation in a way that prevents
leaking water from dripping onto the control module. To do
this, align the upper gate valve laterally if necessary.
• Complete all welding and soldering work near the pump
prior to the installation of the pump.
CAUTION: Dirt can cause the pump to fail. Flush the
pipe system before installation.
• Choose the correct installation position, with the pump
motor in a horizontal position, from only the positions
shown in (Fig. 3). Direction arrows on the pump housing
indicate the direction of flow.
• If heat insulation work is necessary, only the pump housing
may be insulated. The pump motor, module, and
condensate drainage openings must remain uncovered.
Installation and operating instructions
English
37
Tabla de contenido
loading

Tabla de contenido