Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of
those who are hypersensitive to chemicals.
Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under the
indoor unit.
It may cause incomplete combuston or deformation of the unit
due to the heat.
Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.
The appliance is not intended for use by young children
or infirm persons without supervision.
Young children should be supervised to ensure that they
do not play with the appliance.
DISPOSAL Do not dispose this product as unsor-
ted municipal waste. Collection of such waste sepa-
rately for special treatment is necessary.
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities.
Contact you local government for information regarding the
collection systems available.
If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being

2. PARTS NAMES

The air conditioner consists of the indoor unit, the outdoor unit,
the connecting pipe and the remote controller.
Temporary button
C faceplate
S faceplate
Temporary button
Infrared signal
receiver
Operation lamp Timer indicator
Temporary button
Temporary button
Temperature
display
Fig.2-1
Open the faceplate,and you can find the
the display panel.
(Refer to Fig 2-1)
This function is used to operate the unit temporarily in case you
misplace the remote controller or its batteries are exhausted.
Two modes including AUTO and FORCED COOL can be
selected through the TEMPORARY BUTTON.Once you push
this button,the air conditioner will run in such order: AUTO,
FORCED COOL,OFF,and back to AUTO.
1
AUTO
The OPERATION lamp is lit, and the air conditioner will run
under AUTO mode. The remote controller operation is enabled
to operate according to the received signal.
2
FORCED COOL
The OPERATION lamp flashes,the air conditioner will turn to
AUTO after it is enforced to cool with a wind speed of HIGH for
30 minutes.The remote controller operation is disabled.
3
OFF
The OPERATION lamp goes off.The air conditioner is OFF
while the remote controller operation is enabled.
This manual does not include Remote Controller
Operations,
see
Owner's manual>> packed with the unit for details.

3. OPERATION RANGE

Use the system in the following temperature for safe and
effective operation.
Table 3-1
Temperature
Outdoor
temperature
Mode
Cooling operation
21°C 43°C
Heating operating
(cooling only
-5°C 24°C
type without)
1
If air conditioner is used outside the above conditions, it
may cause the unit to function abnormally.
The phenomenon is normal that the surface of air
2
conditioning may condense water when the relative larger
humidity in room, please close the door and window.
3
Optimum performance will be achieved within these
operating temperature range.
4
Water system operating pressuer: Max: 1.6MPa, Min:
0.15MPa.

4. HINTS FOR ECONOMICAL OPERATION

The following should be noticed to ensure an economical
operation.
13
temporary button on
NOTE
the
<<Remote
Controller
Room
water inlet
temperature
temperature
17°C 32°C
3°C 20°C
0°C 30°C
30°C 70°C
NOTE