Trouble Shooting - Stanley EZM4000 Manual De Instrucciones Y Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
O R I G I N A L I N S T R U C T I O N

6. TROUBLE SHOOTING

PROBLEM
The tool does not work
Air is coming out of the
safety valve
The trigger does not work
The blind rivet nut cannot be
placed onto the mandrel
The blind rivet nut is not set
correctly
The tool does not completely
release from the set rivet nut
after trigger is released
The air supply unit cannot be
turned 360°
The tool does not perform
well consistently
CAUSE
The tool has not been connected to the air
connection
The air supply closing valve is still closed
There is insufficient air pressure
The air pressure is too high
There is insufficient air pressure
The incorrect mandrel/anvil set has been
installed
Stroke is not set correctly
There is insufficient air pressure
The capacity of the tool has been exceeded
Rivet nut has not set correctly
The tool is still under air pressure
Requires service
CORRECTIVE ACTION
Connect the tool to the air connection
Open the air supply closing valve
Use the correct air pressure 5-7 bar
Use the correct air pressure 5-7 bar
Use the correct air pressure 5-7 bar
Install the correct mandrel/anvil set
Set correct stroke
Use the correct air pressure
Use the correct tool
Push release button
Close the air supply closing valve and
depressurize the tool by operating the
trigger
Contact a service centre
E N G L I S H
13
Tabla de contenido
loading

Tabla de contenido