Configuring MODE 5
SELECT
MODE CONFIG
9
MODE CONFIG
MODE:1
6
9
9
MODE CONFIG
SETUP
9
MODE5 CONFIG
P1:3.0 bar
MODE5 CONFIG
DP1:0.5 bar
MODE5 CONFIG
P2:2 bar
MODE5 CONFIG
DP2:0.5 bar
MODE5 CONFIG
LOGIC:ALTERN.
MODE5 CONFIG
DRY LOGIC:COS
60 | ENGLISH
• Press the
• Press the
• Press the
MODE:5
(from modes 1 to 6)
• Press the
• Press the
• Press the
• Set the first activation threshold to a specific pressure.
• This parameter defines the first pressure threshold (P1), above which both
electric pumps are deactivated.
• If the pressure is below this set value (P1) minus the differential value
(DP1), a single pump is activated according to the alternating logic.
Default 3 bar
• Set the differential value (DP1) to a specific pressure.
• This parameter defines the difference between the activation and deactiva-
tion levels with respect to the first activation threshold (P1)
Default 0.5 bar
• Set the second activation threshold to a specific pressure.
• This parameter defines the second pressure threshold (P2), above which
one of the two electric pumps is deactivated.
• If the pressure is below this set value (P2) minus the differential value
(DP2), the second pump is activated.
Default 2 bar
• Set the differential value (DP2) to a specific pressure.
• This parameter defines the difference between the activation and deactiva-
tion levels with respect to the second activation threshold (P2)
Default 0.5 bar
• If the system has two electric pumps, enable (ALTERN.) or disable (SIN-
GLE) the alternating logic.
• Set whether the dry running stop logic is based on the motor current read-
ing (CURR) or cosφ reading (COS)
key to confirm the choice and enter the submenu.
key to enter the submenu and change mode.
or
key to select mode 5
key to confirm the choice of MODE:5
key to continue with the configuration
key to enter the mode 5 configuration submenu
Range 0–40 bar
Range 0-P1
Range 0–40 bar
Range 0-P2
Step 0.1
Step 0.1
Step 0.1
Step 0.1