FEATURES
INCREASE THE DISTANCE
Increased terminal distance to each of the 10 outputs, up to 3 terminals on one output.
PROGRAMMING
Programming of home terminals: To select the programming mode we must configure the dipswitches
of the decoder. Make sure that the DL LED shows that the programming has been completed and
remains fixed.
Sequential mode:
With the decoder powered and the LED on, Press the PGM button for more than 1 second and less
than 10 seconds. When the button is released, the decoder starts, for each of the 10 outputs, the
terminal programming.
The address assigned to each of the outputs depends on the dipswitches configuration. See
ADDRESSES TABLE
Direct mode:
free programming of terminals.
With the decoder powered up and the LED lit, set minidip number 8 of the "DECODER" dipswitch to
ON (Direct mode), minidip 8 of the "BLOCK" dipswitch to ON.
There are two ways of programming an output:
- If the terminal has a programmed address already; by sending an F1 command, auto-on or Guard
unit call (key), the decoder will pick up the terminal address and store it in the output that has
received the command.
- If the terminal does not have an address, we can carry out the inverse programming with the panel.
Once we have finished the programming, put the dip 8 of the dipswitch BLOCK to OFF.
BLOCK THE INSTALLER MENU:
To avoid possible errors or misuse by the user, the access to the installer menu on the monitor can be
controlled by the decoder.
Sequential mode:
- To block the installer menu: After programming the decoder outputs, the installer menu will be
blocked.
- To unblock the installer menu: Press the programming button (PGM) on the decoder for 10
consecutive seconds to access the installer menu from the monitor. After 30 minutes it will be
locked again.
Direct mode:
- To block the installer menu: Minidip 8 of dipswitch "BLOCK" to OFF.
- To unblock the installer menu: Minidip 8 of dipswitch "BLOCK" to ON.
ISOLATION BETWEEN TERMINALS
If a short circuit, voltage lower than 15 Vdc or over consumption (peak consumption greater than
2 A) is detected in any of the 10 outputs, this will be isolated from the rest.
Every decoder output has 1 red LED, if it is on, it indicates that the output has a problem. We can
disconnect the output or turn off the decoder to recover it. If the short-circuit occurs in the cable without
having a terminal connected or there is a telephone connected, once the short-circuit is eliminated, the
output recovers automatically.

TECHNICAL SPECIFICATIONS

The set-up process can be completed using either a screw fitting or a DIN rail installation
Dimensions: DIN RAIL 10
Supply voltage
Standby consumption
Maximum consumption
Note: Máx 2 A per output.
8
DECODER/AISLADOR DUOX PLUS 10S
remote programming of terminals.
24 Vdc
912 mW
1.368 mW