3.4. GENERAL INFORMATION

Information
R200/1-BC,
R300/1-BC
max. Weight [kg]
1,4
Length [mm]
111
Depth [mm]
111
Height [mm]
145

3.5. CONNECTION VALUES

Information
Inlet
Outlet
Outlet relief valve
Version FKM seat,
Version EPDM seat

3.6. PERFORMANCE VALUE

SINGLE STAGE LINE REGULATOR
Information
Nominal fl ow
Inlet pressure (max.)
Outlet pressure (max.)
DUAL STAGE LINE REGULATOR
Information
Nominal fl ow
Inlet pressure (max.)
Outlet pressure (max.)

3.7. OPERATING CONDITIONS

Information
Temperature range
Relative humidity (max.)
R200/2-BC,
R500/1-BC
R300/2-BC
2,3
1,3
205
111
111
55
145
165
Value
1/8", ¼", 3/8", ½"
3, 6, 8, 10, 12
4,8; 6,4; 8,0
1/8", ¼", 3/8", ½"
3, 6, 8, 10, 12
4,8; 6,4; 8,0
1/8", ¼", 3/8", ½"
3, 6, 8, 10, 12
Value
20 (Air)
R300 - 300
R200 - 200
R500 - 50
200 (depends on Inlet pressure)
Value
20 (Air)
R300 - 300
R200 - 200
14
Value
-20 till +60
98
13/298
R200/1-SS,
R200/2-SS,
R300/1-SS
R300/2-SS
1,3
2,2
111
205
111
111
145
145
Unit
Fitting inch
Fitting mm
Hose nozzle
Fitting inch
Fitting mm
Hose nozzle
Fitting inch
Fitting mm
Unit
m3/h
bar
bar
Unit
m3/h
bar
bar
Unit
°C
%
R500/1-SS
EN
1,3
111
55
165
Tabla de contenido