CONNECTIONS
The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer.
By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75
⚠
Chimney connection
⚠
The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
The stove must be connected to a single flue. It is forbidden to connect the stove to a flue shared with other combustion
⚠
appliances or with hood exhausts.
The flue must be inspectable for cleaning.
Electrical connection
The plug of the stove's power cable must only be connected after the installation and assembly has been completed of the appli-
ance and must remain accessible after installation.
To make the electrical connection, proceed as described below:
First connect the power cable to the plug on the back of the stove and then to a wall socket.
Supply power to the stove by turning the switch to position (I).
⚠
When the stove is not in use, it is advisable to disconnect the power cable.
⚠
Take care that the power cord (and any other cables outside the equipment) do not come into contact with hot surfaces.
⚠
Ensure that the electrical system is grounded.
For direct connection to the mains, it is necessary to provide a device that ensures disconnection from the mains, with a
contact opening distance that allows complete disconnection under the conditions of over-voltage category III, in accordance
⚠
with installation rules
If the power supply cable is damaged, it must be replaced by the manufacturer or its technical assistance service or in any
⚠
case by a person with similar qualifications, so as to prevent any risk.
It is recommended that authorized personnel pay special attention to the electrical connections after any work on the product.
Connection of external thermostat
To manage the stove using an external thermostat (optional), connect it to the appropriate terminals on the board, as shown in the
Electric scheme.
Connect an open/closed external thermostat, therefore potential-free.
If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to
the appropriate connector on the rear side of the stove; the reading must therefore be activated in the temperature setting
screen, by choosing the "EST" value. The display will not show the room temperature but the writing T ON (when the contact
⚠
is closed) or T OFF (when the contact is open).
Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we recommend you use a
thermostat with a minimum offset of 3°C if you intend to use the "comfort clima" function.
Use and maintenance manual R 1000 Pro
Switch
Power plug
Fuse
EN
Rev.1 29/07/2021
Pag.35