STEINEL RS 200 SC/C Manual De Instrucciones página 51

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 147
Note:
To rule out malfunctioning, a minimum distance of 3 m
must be allowed from the Wi-Fi router and the access
points.
Factory settings (state on leaving the factory)
Reach:
Main light time setting:
Basic light time setting:
Twilight level:
Basic light dimming level:
Commissioning/power interruption
The settings and current operating status of the LED light
are saved automatically in the event of power failure or dis-
connection from the power supply. Settings are reactivated
as soon as the mains power supply is restored.
Reach setting (sensitivity)
Reach is the term used to describe the diameter of the
more or less circular detection zone produced on the
ground after mounting the SensorLight at a height of 2 m.
– Set to maximum = max. reach (4 m)
– Set to minimum = min. reach (1 m)
Time setting
The time (stay-ON time) can be set to any period from
approx. 5 seconds to a maximum of 60 minutes. Every
movement detected re-activates the light.
Note:
Note: after the unit switches OFF, it takes approx.
1 second before it is able to start detecting movement
again. The unit can then switch ON again in response to
movement.
The shortest time setting is recommended when adjusting
the detection zone and performing the functional test.
max.
10 sec.
1 min.
2,000 lux
50 %
– 21 –
Index
Tabla de contenido
loading

Tabla de contenido