Intended Use; Power Supply - Makita HR2652 Manual De Instrucciones

Ocultar thumbs Ver también para HR2652:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
ENGLISH (Original instructions)
SPECIFICATIONS
Model:
Capacities
No load speed
Blows per minute
Overall length
Net weight
Safety class
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
Specifications may differ from country to country.
The weight may differ depending on the attachment(s). The lightest and heaviest combination, according to
EPTA-Procedure 01/2014, are shown in the table.

Intended use

The tool is intended for hammer drilling and drilling in
brick, concrete and stone.
It is also suitable for drilling without impact in wood,
metal, ceramic and plastic.

Power supply

The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
Noise
The typical A-weighted noise level determined accord-
ing to EN62841-2-6:
Sound pressure level (L
Sound power level (L
) : 102 dB (A)
WA
Uncertainty (K) : 3 dB (A)
NOTE: The declared noise emission value(s) has
been measured in accordance with a standard test
method and may be used for comparing one tool with
another.
NOTE: The declared noise emission value(s)
may also be used in a preliminary assessment of
exposure.
Concrete
Core bit
Diamond core bit (dry type)
Steel
Wood
) : 91 dB (A)
pA
HR2652
HR2653
0 - 1,200 min
0 - 4,600 min
604 mm
3.0 - 4.2 kg
3.1 - 4.3 kg
WARNING:
Wear ear protection.
WARNING:
The noise emission during actual
use of the power tool can differ from the declared
value(s) depending on the ways in which the tool is
used especially what kind of workpiece is processed.
WARNING:
Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (tak-
ing account of all parts of the operating cycle such
as the times when the tool is switched off and when
it is running idle in addition to the trigger time).
Vibration
The following table shows the vibration total value
(tri-axial vector sum) determined according to applica-
ble standard.
Model HR2652
Work mode
Vibration
emission
Hammer
13.1 m/s
drilling into
concrete
(a
)
h, HD
Chiselling
10.9 m/s
(a
)
h, CHeq
Model HR2653
Work mode
Vibration
emission
Hammer
11.2 m/s
drilling into
concrete
(a
)
h, HD
Chiselling
9.3 m/s
(a
)
h, CHeq
8 ENGLISH
HR2653T
26 mm
68 mm
80 mm
13 mm
32 mm
-1
0 - 1,100 min
-1
0 - 4,500 min
630 mm
3.2 - 4.4 kg
3.3 - 4.5 kg
/II
Uncertainty (K) Applicable
standard
2
2
1.5 m/s
EN62841-2-6
2
2
1.5 m/s
EN62841-2-6
Uncertainty (K) Applicable
standard
2
2
1.5 m/s
EN62841-2-6
2
2
1.5 m/s
EN62841-2-6
HR2663
-1
-1
666 mm
Tabla de contenido
loading

Este manual también es adecuado para:

Hr2653Hr2653tHr2663

Tabla de contenido