Operating instructions
Wet-vacuuming
! Insert power plug
! To deactivate Power Filter
Clean
! Switch on the machine and
start using it
All manuals and user guides at all-guides.com
NT 65/2 Eco ME
To deactivate Power Filter Clean
Slider (1) position - up.
Note:
— It is advisable to deactivate the
- Power Filter Clean - function
when vacuuming with the
upholstery or crevice nozzle or
if predominantly water is to be
sucked out of a container.
Upon reaching the maximum liquid
level the unit automatically turns
itself off.
! Switch the appliance off and
empty the container.
Automatic shutoff is reset by
turning off the unit.
! Clean and dry the flat pleat
filter and the electrodes as well
as the container after finishing
wet vacuuming jobs.
English
Warning!
— During vacuuming it is not
permitted to ever remove the
flat pleated filter.
— The paper filter bag and the
membrane filter (optional
accessories) respectively must
always be removed for
vacuuming wet dirt. The use of
a special filter bag (wet type) is
recommended
(see filter systems).
— The unit does not switch off
when the container is full when
non-conductive liquids (e.g.
drilling emulsion, oils and
greases) are vacuumed. The fill
level must be regularly checked
and the container emptied
before it is too full.
— On request, the unit can be
retrofitted by maintenance
service with a shutoff for
dielectric liquids.
14