Basics
The redox-potential or oxydation/reduction potential (ORP) is an electrical value which is a
parameter for the oxydation and reduction processes in the aquarium.
The redox-potential is of special interest in:
-
Assessing the quality of salt water in aquaria. The ideal range is between 300 mV and 400 mV.
If needed, the range can be increased by injecting Ozone into the protein skimmer. The higher
the value, the higher the percentage of oxydation, the „cleaner" the water is.
-
The redox-potential is used in denitrifying filters to check the acidity. The ideal values are
between -300 mV and -100 mV.
-
In swimming pools the redox-potential can be used for sterilization by regulating the amount of
chlorine added by maintaining +700 mV.
2.
Features
Aqua Medic Computers are micro-processor controlled units. They are safe, reliable and meet all
requirements of professional measuring and regulating devices.
The Aqua Medic mV-Computer is supplied with a redox probe and standard solution. The ozonizer
(not included) can be connected to the female side of the main power plug.
Technical Data
Micro-processor controlled
Line voltage:
Output relay-controlled:
Measurement range:
Adjustment range:
Adjustments:
Hysteresis:
Adjustment directions
adjustable:
Redox probe:
Data memory:
All manuals and user guides at all-guides.com
230 V/50 Hz
5 A, 1,000 W
- 1,999 up to + 1,999 mV
- 1,000 up to + 1,000 mV
on/off
adjustable
- upwards, with Ozone filtration mV-value may increase
- downwards by adding reducuing substances
Plastic shaft (Polysulfon)
power loss protection
7