Dual Installation; Electrical Requirements - Sub-Zero Classic Serie Guia De Instalacion

Ocultar thumbs Ver también para Classic Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Site Preparation

Dual Installation

If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 2"
filler strip is recommended between
(51)
units. Dual installations without a filler strip can only be
accomplished using two units with opposite hinges. Refer
to the illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the
find a showroom section of our website, subzero.com.
For questions regarding the installation, call Sub-Zero
Customer Care at 800-222-7820.
WITHOUT FILLER STRIP
Opposite hinges
8 | Sub-Zero Customer Care 800.222.7820
FILLER STRIP
Same side hinges

Electrical Requirements

Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded.
WARNING
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly quali-
fied persons in order to avoid a hazard.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
7"
E
(178)
6"
(152)
1
75
/
"
2
(1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
Tabla de contenido
loading

Tabla de contenido