INSTALL THE HOOD (VERTICALLY DUCTED HOODS ONLY)
1. DO NOT REMOVE the protective plastic film
covering the decorative flues at this time.
2. Align the hood and center it above the hood
mounting bracket. Gently lower the hood until it
securely engages the bracket.
SIDE VIEW
HOLE LOCATIONS Ø5/16"
3. If a framing member is not present: With the hood
hanging in place, drill through both holes located
in the inside lower back of hood using a 5/16" drill
bit. Insert the included drywall anchors into the
drilled holes (one for each hole).
4. Install (2) washers and (2) #8 x 1½" mounting
screws through the back of the hood and into the
drywall anchors. Verify that the hood is centered
and leveled. Tighten all screws completely.
6" ROUND
DUCT
(VERTICAL
DUCTING)
5. Measure and cut metal ductwork. Set ductwork
aside.
6. Plug hood power cord into the outlet.
All manuals and user guides at all-guides.com
INSIDE
BACK
OF
MOTOR/
HOOD
BLOWER
ASSEMBLY
TYP.
MOUNTING BRACKET
7. Remove the upper flue from inside the lower flue.
Install the lower flue bracket to the lower flue using
(2) flue bracket screws (#8 x 3/8"). Ensure that
the bracket is positioned inside of the lower flue
flanges - with the slots on top. Carefully replace the
upper flue inside the lower flue. Remove protective
plastic film covering the lower flue only.
8. Place both flues into the recessed area of hood top.
9. Carefully rotate bottom of flue assembly out and
slide metal duct section into flue assembly.
UPPER FLUE MOUNTING
BRACKET - FRONT VIEW
10. Connect duct section to duct connector and duct
rough-in. Use duct tape to make sure all joints are
secure and air tight.
11. Slide the upper flue upward until it is aligned with
its upper flue mounting bracket. The bracket should
be inside the flue. Secure the upper flue to the
upper flue mounting bracket using (2) #8 x 3/8"
mounting screws.
12. Remove protective plastic film covering the upper
flue and the hood.
13. Reinstall grease filter by aligning rear filter tab with
slot in the hood, push in the metal latch tab, push
filter into position and release. Make sure filter is
securely engaged after installation.
10
LOWER FLUE
LOWER FLUE
UPPER FLUE