FOR BATTERY TOOLS
The ambient temperature range for the use and storage of
o
o
tool and battery is 0
C-45
The recommended ambient temperature range for the
charging system during charging is 0
ENVIRONMENTAL
PROTECTION
Waste electrical products must not be disposed
of with household waste. Please recycle where
facilities exist. Check with your local authorities or retailer
for recycling advice.
TROUBLESHOOTING
The following table gives problems and actions that you
can perform if your machine does not operate correctly.
Warning: Switch the machine off and remove the
battery prior to any troubleshooting.
Symptom
Possible
causes
Battery is not
charged. LED
light is not on.
Pump is
Sprayer will not
over heated,
turn on when
damaged, or
power button is
non-functional.
pressed.
Tank is already
pressurized
so the pump
is turned off
automatically.
No liquid is in
tank.
Shut-off is
clogged
Sprayer turns
on but will not
Nozzle is
spray.
clogged.
Pump is not
attached tightly
to the tank
20V Yard Sprayer
C (32°F-113°F).
o
o
C-40
C (32°F-104°F).
Solution
Charge Pump
Allow the battery
to cool down.
Replace Pump if
it is damaged or
non-functional.
Depress the
lever to see if the
sprayer starts
spraying.
Add liquid to
tank.
Clean the shut-
off
Clean the
nozzle..
Tighten pump to
tank.
Tank has
not been
pressurized yet.
Air leaking from
Sprayer turns
tank at seal.
on but only
sprays at a low
Tank seal is
pressure.
damaged.
Shut-off is
clogged.
Nozzle is
clogged.
Cracked, swollen
or faulty hose.
Hose leaks at
the tank
Damaged
connection.
Cracked, swollen
or faulty hose.
Hose leaks at
the shut-off.
Damaged
connection.
Tank has
not been
pressurized yet.
Nozzle is
partially
Poor Spray
clogged.
Performance
Nozzle is
damaged.
Shut-off is
clogged
Allow time
for pump to
pressurize tank
(at least 20
seconds).
Tighten pump to
tank.
Replace tank
seal.
Clean the shut-
off
Clean the nozzle.
Replace shut-off
assembly.
Replace shut-off
assembly.
Replace shut-off
assembly.
Replace shut-off
assembly.
Turn on pump.
13
Clean the nozzle.
Replace the
nozzle.
Clean the shut-
off
EN