3. INSTALLATION

3.1 SELECTING A LOCATION

The pump must be installed:
• In front of the filter, heating system and/or water treatment unit
• At a distance of 2 meters from the edge of the pool, to prevent water from splashing the unit. Some
standards allow other distances. Consult the standards in force in the country of installation.
• Ideally, 30 cm below the water level.
• Outside an area susceptible to flooding or on a stand with drainage.
• In a well ventilated place, to allow the pump to cool.
The pump must not be installed:
• In an area susceptible to rainfall and splashing.
• Near a heat source or source of inflammable gas.
• In an area that cannot be cleaned or kept free of leaves, dry vegetation and other inflammable
items.
• In Area 0 and Area 1 (FIGURE 1).
AREA 2
2.5 m
2 m
2 m
AREA 2
AREA 1
8
AREA 1
AREA 0
AREA 0
FIGURE 1 - INSTALLATION ZONES
CEILING
1.5 m
1.5 m
2.5 m
Skimmer
2 m
2 m
AREA 1
Installation and general maintenance manual
AREA 2
AREA 2
- POOL PUMPS