Wiring Requirements
CAUTION:
• Use copper conductors only.
• Wiring cable temperature should support at least 105°C.
• Tighten the wire to a torque value 4.5 lb.in.
• The wire gauge for the terminal block should range between
12 and 24 AWG.
To insert power wire and connect the 12~48VDC at a
maximum of 1.5A DC power to the power terminal block, follow
these steps:
• Use a flat-head screwdriver to loosen the wire-clamp screws.
• Insert the negative/positive DC wires into the PWR-/PWR+
terminals, respectively.
• Tighten the wire-clamp screws to prevent the wires from
loosening.
ATTENTION: Use a power supply from 12~48VDC.
The device power shall be supplied by SELV
circuit.